In the detailed photo of the sensor above, from left to right, are a visible red LED (for delivering the flashing cue), an IR LED with a sheath to narrow its output beam, and a photodiode. The sheathed emitter coupled with the wide area sensor gave me the best results i.e. the greatest variance in sensor value in response to a closed, moving eye.
I’m actually amazed by how much variance there is; I suspect that a significant amount of IR is penetrating the eyelid and reflecting off the sclera.
dakle ako je ovo tacno, detekcija se radi onako kako sam pretpostavio na pocetku (probija ir kroz kapak i odbija se od beonjace/roznjace i zenice i hvata na ir tranzistoru) to sto ces da napenalis struju u IR ce upravo kako sam ti i rekao dodatno ukinuti mogucnost sprave da detektuje pomeraj oka. fora je da taj ir uopste ne svetli jako a mnogo bitnije da nikako ne svetli prema trandzi, dakle da ga izolujes u krug tako da bude jako usmeren u tvoje oko. time sto ces da ga otpanjis na trandzi non stop imas max signal i od detekcije nista posto ti celo oko svetli ir. to kada izolujes ir led tako da ne sveti u stranu vec da bude usmereno obrati paznju da moras sa ir neprovidnim materijalom (papir, plastika i slicno nisu neprovidni za ir, uzmi neku alu foliju pa preko nje selotejp to je najbolje resenje)